Escort Silent Diesel Generator
Power | 40 kVA |
DG Set Dimensions ( L X B X H) | yes |
Rotation from Flywheel End | yes |
Bore X Stroke Size | yes |
Country of Origin | Made in India |
Features:
- Reliable, Robust & Rugged engines designed to deliver continuously in arduous environment
- Better Block Loading Capability
- Compact engine - Engineered for Optimized Power Solutions
- Low Ownership Cost
- Low Oil & Fuel consumption
- Continuous duty Power rating
- Minimal vibrations and lower noise levels
- Easy Serviceability & Repairability
- Standardized Design for complete range
- Wide after-sales & parts support
25 Kva Escorts Silent Diesel Generator
Power | 20 kVA |
L x W x H (mm) | yes |
Lube oil Grade to be Used | yes |
Governor Type and Class | yes |
Fly Wheel Housing | yes |
Country of Origin | Made in India |
Other Essentials:
Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
How to Calculate Load:
Put on only those equipment's which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you'll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
10 kVA Escorts Silent Diesel Generator
Power | 10 kVA |
L x W x H (mm) | yes |
Lube oil Grade to be Used | yes |
Governor Type and Class | yes |
Fly Wheel Housing | Yes |
Country of Origin | Made in India |
Other Essentials:
Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
How to Calculate Load:
Put on only those equipment''s which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you''ll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.
35 kVA Escorts Silent Diesel Generator
Power | 35 kVA |
L x W x H (mm) | yes |
Lube oil Grade to be Used | yes |
Governor Type and Class | yes |
Country of Origin | Made in India |
They are suitable for small & medium Industries, Rice Mills, Cold storages, Stone Crushers, Railways, Defence, Telecom, IT Segment, Hospitals, Clinics, Schools, Colleges, Cinema Halls, Shopping Malls, Residential Apartments etc.
Escorts ELG 7.5 Diesel Generator
Product Brochure
Bore and stroke | 91mm And 110mm |
Weight Approx | 550kg |
Compression Ratio | 17.5:01 |
Genset Brand | Escorts |
Battery | 88Ah |
Rated Speed | 1500 RPM |
No. Of Cylinders | 2 |
Emission Norms | CPCB-II |
Engine Model | G12 II |
Fuel Tank Capacity | 100L |
Power (kVA) | 7.5 kVA |
Frequency | 50 Hz |
Rated Power | 6 kW |
Total Displacement | 1430cc |
Lube Oil Sump Capacity | 6.5L |
Cooling System | Water Cooled |
FIP | MICO BOSCH Inline Pump And Mechanical-A1 Governing |
Dimensions | 1500x930x1150 mm (LxWxH) |
Model Number | ELG-7.5 |
Flywheel Housing | SAE 3/ SAE 10 |
Starting System | 12V DC |
- State-of-the-art ADI technology for unmatched power & diesel economy
- Plateau-honed wet liners for low lube oil consumption
- Designed for 100% continuous operation & longer service intervals
- Class Al governing with 45 regulation that gives stable operation in fluctuating load conditions
- Efficient cooling mechanism and no frequent top-ups.
Escorts silent DG sets. The most advanced in its class. Smart operations:
- Microprocessor based auto-start controller for AMF operation
- Remote start & stop facility
- In-built event log(optional)
Environment-friendly
- Less noise with low vibrations
- Cleaner emissions
- Meets CPCB-II norms
Safe-to-use
- In-built safety features like HWT, LLOP LFL, CHF & RWL
- Equipped with fire-retardant form
Versatile
- Compact
- Easy access to all service points
- Compatible with any AMF/PIU logic controller
Benefits to Customer: Big on Savings
- The most fuel-efficient in its range
- Low operating cost
- Compact size to fit low space criteria in roof-to applications
- High reliability with low maintenance
Excellent Service Support
- Peace of mind with 24x7 single-window service
- Widest network of genset service dealers
- Well-trained & equipped technicians at all dealer locations
- Multi-tier availability of spare parts & efficient supply chain management
- Advanced communication facilities to deliver prompt response
- Call monitoring system and robust escalation procedure to eliminate pending calls Option of AMC/CAMC
- Also available on lease and/or hire
500 Kva Diesel Generator
Minimum Order Quantity: 10 Set
Oil and oil filter change period | 2 months |
Dimensions (L x W x H) | yes |
Length x Width x Height (mm) | yes |
Dimension (L X W X H ) | 5650 x 2000 x 2558 |
Dimensions (H x W x D) | 2558 x 2000 x 7200 |
Country of Origin | Made in India |
Additional Information:
- Production Capacity: 100
- Delivery Time: 2 week
Power | 20 kVA |
L x W x H (mm) | yes |
Lube oil Grade to be Used | yes |
Governor Type and Class | yes |
Country of Origin | Made in India |
Other Essentials:
Engines are tested as per BS5514, IS: 10002 and IS01000B respectively.
Superior quality alternators are used confirming to lS13364, IS4722 & BS5000 standards.
Technologically advanced control panels with Deep-sea / Procom controller. Heavy, robust and sound efficient DG sets confirming to CPCB-II norms & Rule 95 of environment protection of GSR no of 771(E) & GSR 232(E).
How to Calculate Load:
Put on only those equipment''s which you want to run on the Powerlux Silent Generator.
Go near the distribution box where you''ll find four colored cables; Red, Yellow, Blue & Black.
Put the clamp meter around the Red, Yellow & Blue cable one by one and note down the ampere rating.
Now add the numbers in case of single phase requirement or pick the highest in case of three phase requirement.
Select your kVA from the above given ampere chart and see under which rating your requirement falls.